Filter Results By:

Products

Applications

Manufacturers

Showing results: 961 - 975 of 1016 items found.

  • AC and DC Voltage Divider

    WAFRC - Wuhan Sangao Electrical Test Installations Limit Co.

    AC and DC voltage divider, Mainly composition by the high stability of passive resistance capacitance voltage divider and high precision digital kV table. The divider is passive resistance capacitance, Connected digit kV meter by coaxial cables. Which can be directly read out the AC, DC data measured from the table. This instrument has high precision, convenient operation, can be used instead of the electrostatic voltmeter. Device and the measuring line, power line, manual loaded box in light aluminum alloy, easy to carry and use. This equipment is mainly used for AC and DC high voltage measurement, and is suitable for power system's field measured and Institutions of higher learning laboratory's AC and DC high voltage measurement.

  • Digital Broadcast Analyzer

    Anritsu Corporation

    Spectrum Analyzer: 9 kHz 4 GHzInterference Analyzer with Interference MappingHigh Accuracy Power Meter, 2-port Transmission MeasurementsCoverage Mapping, Channel Scanner, GPS, AM/FM/PM Analyzer3GPP, 3GPP2, WiMAX, signal analyzersTracking Generator: 500 kHz 4 GHzDigital TV ISDB-T, DVB-T/H analyzersCPRI RF MeasurementsField-proven design: Three-hour battery life, rugged, compact, lightweight, daylight viewable displayIntuitive menu-driven touchscreen user interfacePIM Alert (a downloadable easyTest script)Standard three-year warranty (battery one-year warranty)

  • VDSL Tester

    X5008 - Shinho Company

    X-5008 VDSL tester specially designed for slid line test (xDSL include: ADSL, ADSL2, ADSL2+, READSL, VDSL2 etc) and maintenance It provides xDSL test, PPPoE dial test, DMM test, Modem emulation, line voltage indication and so on. X-5008 VDSL Tester also introduces the Optical Power Meter and Visual Fault Locator function into the unit, as well as the TDR function. It is one mufti-function tester with smart size, true color LCD and powerful management software as well as the 6600mAh rechargeable battery etc.

  • Surge Voltage Generator

    SSG 3000 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 3000. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* high surge energy in each voltage range

  • Multi Channel Optical Fibre Verification

    LXinstruments GmbH

    The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.

  • Battery Capacity Analyzer

    601B - B&K Precision Corporation

    The 601B Battery Capacity Analyzer addresses the need to test and maintain sealed lead acid (SLA) batteries used in backup power UPS, emergency lighting, fire alarms, security systems, and many other electrical systems. By quickly characterizing a battery's response to a load resistance and measuring the battery's internal resistance, this meter displays the remaining battery capacity as an indicator of the battery’s health. Powered by the battery under test, the 601B supports testing of both 6 V and 12 V storage type lead acid batteries.

  • All-in-One Field Optical Tester

    SMT-50 - Atomowave Co.,Ltd.

    Power meter is the best essential tool for all technicians installing or maintaining optical fiber network. SMT-50 Multi Tester is made for the best performance of different parameters and demanding applications on fiber measurement. It is designed for handy size with simplicity and accuracy. SMT-50 provides 4 exquisite functions to optimize the time of all technicians and can be tested at up to 6 wavelengths in operating. Six main wavelengths (850, 1300, 1310, 1490 1550 and 1625 nm) used in FTTX networks can be tested of passive optical networks (PONs)​

  • Digital RF Power &VSWR Measurement System

    PowerMaster II - Array Solutions

    Thank you for purchasing the Array Solutions PowerMaster II RFPower/VSWR Indicator. The PowerMaster II represents a breakthrough in features for measurement of the performance of your transmitting system. Microprocessor control insures fast capture time and low power consumption. With the ability to monitor your VSWR and power levels at all times, you will know that your transmitter, RF source, and load, or antenna systems are operating effectively and safely. In addition, the power and VSWR relay alarms can quickly shut down your power amplifier system and alert you to the alarm condition. This places an additional layer of protection in your transmitting system to help preserve expensive tubes and finals. The PowerMaster II also features the ability to be monitored and controlled from a PC using the software downloadable from our website, and the unique ability to be monitored and controlled over a LAN or from the internet. PowerMaster II firmware updates will be posted for download from the Array Solutions website as they become available. This means that the user can take full advantageof features or enhancements just by installing the firmware update. No need to return the meter to the factory for updates

  • Small/Medium Capacity Type High-Speed Rotation Torque Detector

    TH-2000/1000 Series - Ono Sokki

    The TH-1000 series torque detectors employ a new magnetic phase difference method with improving functionality while maintaining the advantages of Ono Sokki's conventional torque detectors. They incorporate high durability and long service life---the biggest features of our torque detectors. The new magnetic phase difference method does not require AC power supply to an auxiliary motor for rotation detection change. TH-1000 series is a standard type torque detector with the rotation speed range up to 6000 r/min. The TH-2000 series is a high-speed rotation type which can be used for torque characteristic test of high-speed rotating motor such as an EV/HEV motor, a centrifuge machine or the like. The characteristic data of the detector can be automatically set up on the TH-5100 torque meter when power is turned on.

  • PD Signal Detection and Analysis via Ultra-High Frequency, Acoustic Emissions, High Frequency Current Transformer, and Transient Earth Voltage Sensors

    PDiagnostic Series - Power Monitoring and Diagnostic Technology Ltd.

    The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.​

  • Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.

    72-2985 - Tenma

    The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.

  • Internal Antennas

    Pulse Electronics

    Pulse offers a large selection of internal antennas that are designed into an incredibly diverse selection of solutions, from smart home IoT devices to utility meters, from point of sale products to wireless charging.  The PCB antennas, including those made with flexible material, are made to be mounted or adhered against a plastic surface and connect via cable to your PCB, and cover the ISM, WiFi, GNSS, and cellular bands.  The NFC selection for 13.56 MHz will work with both 50 and 80 Ohm radios and include antennas with a ferrite backing to work even when mounted against metal.  The selection of active GNSS patch antennas with cable are perfect for ensuring your device’s whereabouts are accurately tracked.  Finally, the many transmit and receive coils for wireless power charging will add this popular consumer capability to your product, cutting one final cable from design. Use the product finder below to find the perfect internal antenna solution for you.

  • High Voltage EMC Surge Generator

    TM510 - T&M Tools Limited Co

    TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.

  • High Density 1xN mux or 2xN Matrix Switching Systems

    JX Series - Cytec Corp.

    This compact and economically priced series can be used as either 1xN multiplexers, 2xN matrices, or individual switches. As multiplexers, they can be used as a large number of individual muxes or jumpered together to form as large a mux as you need to switch a large number of inputs or outputs to one common port. As a 2xN matrix they allow you to switch any number of signals between two ports of a DVM, DMM, LCR, or other type of meter or supply. Individual relay modules are available for other configurations requiring discrete SPST or SPDT relays with standard or power relays.

  • Test Bench for Starters and Alternators

    MS004 COM - MSG Equipment

    Compact tabletest bench is used for quick and quality diagnostics of starters, alternators and voltage regulators without applying any additional measuring devices. The test bench possess high power, thus, units can be diagnosed under different loads. The equipment has small dimensions, it can be placed both in small service centers and big shops specialized in selling equipment.The bench includes the following diagnostic functions: testing of 12V and 24V alternators under load, 12V and 24V voltage regulators, 12V and 24V starters in idle running mode.Power supply is single-phase 220V, thus, there is no need industrial power supply.The device carries out testing of different alternators under load up to 100A.Connection of the 2nd battery is conducted from outside to the terminals on the bench body to achieve power supply of 24V for more convenient connection. Thus, usage of the 2nd battery is optional.New algorithms of testing have been implemented, meter accuracy has also been improved.

Get Help